REAMS ENTERPRISES INC.
MACON, GEORGIA 312012617
Top Industries (NAICS)
| NAICS Code | Obligations | Awards |
|---|---|---|
| 236220 | $24.42M | 86 |
Contract Awards
35 awards found
THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO REPAIR THE VARIOUS ROADS FOLLOWED IN SECTIONS (CODES ARE MP=MOTOR POOL AND P= PARKING, ROAD).
CH50091-2P -REPAIRS
SECTION TABLE OF CONTENTS DIVISION 01 - GENERAL REQUIREMENTS SECTION 01 10 00 STATEMENT OF WORK 07/2024PART 1 GENERAL1.1 WORK COVERED BY CONTRACT DOCUMENTS1.1.1 PROJECT DESCRIPTION1.1.2 LOCATION1.1.3 CLIN STRUCTURE1.1.4 FUNDING1.1.5 PERIOD O
CLIN 02: BASE BID REPAIR ROOF B33200
0005 FIBER RUN FROM HUT 473 TO TA36
GA OKEFENOKEE NWR COMM. TOWER
4P MILLING & AC 4TH DIV RD-TOPR 0081
REPAVE PICKENS & SCOUTS OUT - TOPR 0082
BASE BID 02 (CONSTRUCTION)
B4255 & 4265 BETWEEN OCCUPANCY MAINTENANCE - TOPR0075
CH50091-2P -REPAIRS
BUILDING 12650 SPRC CONVERSION - MOD TO INSTALL BUFFER TANK FOR TOPR0032.
OPTION CLINS CHANGED TO BASE CLINS.
B21608 REPLACE ROOF
CH50091-2P -REPAIRS
BLDG2603 ROOF REPLACEMENT TOIPR0049-CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL & COORDINATION REQUIRED TO REMOVE/REPLACE ROOF & LIGHT PROTECTION SYSTEMS.
TOPR0047 BLDG5700 PARKING LOT - RESURFACING PRESERVATION OF THE PARKING LOT, ENTRANCE ROADS, AND DRIVE-THRU AREA. CONTRACTOR RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS. ALL WORK SHALL ADHERE TO GUIDELINES SPECIFIED IN APPLICABLE REGULATIONS & CODES.
VARIOUS ELEVATORS-TOPR0045: THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO REPAIR THREE ELEVATORS.
B4295 BETWEEN OCCUPANCY MAINTENANCE-TOPR0037: THE CONTRACTOR SHALL RESTORE WALL FINISHES, ANTI-SLIP FINISHES ON STAIRS, AND POLISH TERRAZZO FLOORING. ALL WORK SHALL ADHERE TO GUIDELINES SPECIFIED IN APPLICABLE REGULATIONS AND CODES.
TOPR0040 BTX UPGRADE- CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO DESIGN AND INSTALL FIRE ALARM INFRASTRUCTURE, EQUIPMENT, AND SYSTEMS AT MULTIPLE BUILDINGS ON FORT JACKSON.
VARIOUS DOORS REPAIR/REPLACE TOPR0038: THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO REPAIR OR REPLACE DOORS AS IDENTIFIED IN SOW.
CEP 3 MTW HEADERS - TOPR0041: PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO RECONFIGURE THE MTW SUPPLY AND RETURN HEADERS AND VALVES TO ALLOW ISOLATION OF INDIVIDUAL PIECES OF PLANT EQUIPMENT.
TOPR0036 CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO INSTALL A DRAINAGE TROUGH, INSTALL A SOLID BASE, AND REPAIR LEAKING DRAIN LINES FOR WASHING MACHINES IN THE LAUNDRY FACILITIES IN BOTH BUILDINGS.
MOD01 B2601 AHU REPLACEMENT- THE CONTRACTOR SHALL INCREASE THE SIZE OF AHU 1 FROM 12.5 TON TO A 32 TON, INCREASE SIZE AHU 2 FROM 12.5 TON TO A 44 TON AND UV1 FROM 25 TON TO A 69 TON IAW UPDATED SOW.
CH50091-2P -REPAIRS
MULTIPLE AWARD TASK ORDER CONTRACT (MATOC) FOR DESIGN-BUILD CONSTRUCTION SERVICES FOR THE DEPARTMENT OF INTERIOR AND FOREST SERVICE
MOD02 SPRC BUILDING CONVERSION EQUITABLE ADJUSTMENT FOR AN UNFORESEEN SPACE LAYOUT CHANGE ORDER AND TO EXTEND THE DELIVERY DATE.
CH50091-2P -REPAIRS
CH50091-2P -REPAIRS
TOPR00029-4282 REPLACEMENT AHU: PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL & COORDINATION REQUIRED TO REMOVE & REPLACE EXISTING HVAC UNITS IN B4282 INCLUDING THE MILITARY POLICE (MP) SECTION, TELECOMMUNICATIONS (ATT) ROOM AND BATTERY ROOM.
TOPR0031-BLDG. 2601 AHU REPLACEMENT: THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO REPLACE THE AIR HANDLING UNITS (AHU'S) IAW SOW.
TOPR0026-4323 MTW LINE REPAIR: THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED TO REMOVE, REPAIR AND REPLACE THE OLD AND DEFECTIVE MEDIUM TEMPERATURE WATER (MTW) PIPING AND INSULATION AT B4323.
TOPR0032-12650 SPRC CONVERSION: THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, MATERIAL, AND COORDINATION REQUIRED IAW SOW FOR BUILDING 12650.
DE05148-1P CORRECTIVE MEASURES GIBSON
CH50091-2P -REPAIRS AND EXPAND CHAPEL
Business Details
- UEI
- UBQRV9HDLDG9
- CAGE Code
- 1CHQ7
- Address
- 847 WALNUT ST
MACON, GA 312012617 - Congressional District
- GA-02
- Phone
- 4046842500
Parent Company
REAMS ENTERPRISES INC.
Data Source
This profile is based on federal contract award data from USAspending.gov.